Note that when the slave loop is in ROUT, it is not controlling. The input to its SP (via CAS or RCAS) is passed through as a percent of PV_SCALE to the percent of OUT_SCALE. This matches what I see in the DOC you sent, either the Master controller is controller or the slave controller is controlling, but not both in cascade manner. I also see that the standard features for cascading controllers (even though the slave is in ROUT, not actively controlling) is not being used as indicated by no connection to the BKCAL_IN of the Master PID. Thus, it would be hard for me to totally understand exactly how the control scheme is working. There are features and techniques in DeltaV, other than not using Integral, to avoid overshoot which might also avoid some of the complexity of the current solution. I would like to suggest that you reach out to your Emerson Local Business Partner or Emerson direct sales person and have them contact me for more direct support of your questions.
↧
Forum Post: RE: PID Structure and Bias
↧
Forum Post: RE: 2400 series modbus comm help
Hi Ric, In addition to my previous response, I would like to note that the scaled integers at address 2 – 11 (the 30000 is just a read only nomenclature) are 16 bit scaled integers. If the value is above the 65535 maximum or if the transmitter is in a critical fault, then the registers will show Maximum Integer -1. Which is often shown as -1. It is possible that the transmitter has a critical fault. To better read the scaled integers at 2 – 11, it is recommended to read the process variables as Floating Point numbers. The two word, single precision, floating point address start at address 247 and go through 266. If you don't already have the MODBUS Interface Tool (MIT), you can find it on the Emerson website here www.emerson.com/.../66752.zip For technical support or to speak directly to our flow support team, please contact us at flow.support@emerson.com or just call the 1-800-522-6277 customer support line and select the ‘technical support’ option. Best regards,
↧
↧
Blog Post: Instrumentation Diagnostics and Safe, Reliable Operations
As technology has advanced in power and sophistication, its ability to self-diagnose and perform predictive diagnostics has too. In a Plant Engineering article, Using diagnostic functions to improve system safety , Emerson’s Mark Menezes shares examples of how these diagnostics are used to self-diagnose instrumentation problems as well as those in the surrounding production process. He opens highlighting the benefits of these diagnostic functions. They improve: …safety, and also can predict failures before they happen, improving availability. In other cases, a plant may design its own diagnostic, adding devices such as pressure relief valves, rupture disks, and corrosion/erosion monitors in critical places to watch for larger things going wrong. Let’s consider all three approaches. Mark shares temperature measurement devices for his first example. Measurement values from temperature measurement sensors—resistance temperature detectors (RTDs) and thermocouples (TCs), are: …very low-amplitude signals that must then be processed and amplified by the transmitter before being sent to the logic solver. The measurement value can be affected by electromagnetic inference, signal spikes and dropouts. Signal processing in the transmitter can help assess these non-temperature related changes: …and simply repeat the last good measurement. This approach provides stability without damping or slow response, but it should not be applied where the measurement can legitimately see fast full-scale excursions. From a self-diagnosing standpoint, issues such as excessive vibration, corroding electrical connections or chemical attack may cause: …the frequency of spikes and dropouts to increase over time. The transmitter can detect and trend this increasing frequency and predict impending failure, alerting maintenance early enough to take action and prevent total signal loss. Mark also describes how the change in resistance in thermocouple wires can be used in diagnosing the sensor. Changes in TC circuit resistance can suggest several things. If resistance goes to infinity, the circuit is open. If resistance decreases from its normal level, there is probably a short circuit. If resistance increases, the wire or termination is probably corroding. These changes may be immediate, but more often they’re gradual, so measuring and trending resistance changes can be used to predict failure and improve availability. Read the article for other examples of how wired or wireless acoustic sensors can be used to monitor pressure relief valve (PRV) and rupture disc pressure relief events and leaks. He also describes how to monitor online and continuously for corrosion and erosion problems in pipelines and vessels. Finally, he shares how these diagnostics from HART smart instrumentation can be used to augment the traditional 4-20mA analog signal used in safety instrumented systems to provide diagnostic health information about the sensors. You can connect and interact with other functional safety and temperature measurement experts in the Safety Instrumented Systems and Temperature groups in the Emerson Exchange 365 community. Related Posts Extending Measurement Device Stability to 15 Years Temperature Measurement Advanced Diagnostics Redundancy and Diagnostics in Safety Instrumented System Sensors Energy Management with Additional Wireless Measurements Avoiding Flameout and Shutdown in Burner Management Applications When the Heat is on, Control with Wireless The post Instrumentation Diagnostics and Safe, Reliable Operations appeared first on the Emerson Process Experts blog.
↧
Blog Post: Instrumentation Diagnostics and Safe, Reliable Operations
As technology has advanced in power and sophistication, its ability to self-diagnose and perform predictive diagnostics has too. In a Plant Engineering article, Using diagnostic functions to improve system safety , Emerson’s Mark Menezes shares examples of how these diagnostics are used to self-diagnose instrumentation problems as well as those in the surrounding production process. He opens highlighting the benefits of these diagnostic functions. They improve: …safety, and also can predict failures before they happen, improving availability. In other cases, a plant may design its own diagnostic, adding devices such as pressure relief valves, rupture disks, and corrosion/erosion monitors in critical places to watch for larger things going wrong. Let’s consider all three approaches. Mark shares temperature measurement devices for his first example. Measurement values from temperature measurement sensors—resistance temperature detectors (RTDs) and thermocouples (TCs), are: …very low-amplitude signals that must then be processed and amplified by the transmitter before being sent to the logic solver. The measurement value can be affected by electromagnetic inference, signal spikes and dropouts. Signal processing in the transmitter can help assess these non-temperature related changes: …and simply repeat the last good measurement. This approach provides stability without damping or slow response, but it should not be applied where the measurement can legitimately see fast full-scale excursions. From a self-diagnosing standpoint, issues such as excessive vibration, corroding electrical connections or chemical attack may cause: …the frequency of spikes and dropouts to increase over time. The transmitter can detect and trend this increasing frequency and predict impending failure, alerting maintenance early enough to take action and prevent total signal loss. Mark also describes how the change in resistance in thermocouple wires can be used in diagnosing the sensor. Changes in TC circuit resistance can suggest several things. If resistance goes to infinity, the circuit is open. If resistance decreases from its normal level, there is probably a short circuit. If resistance increases, the wire or termination is probably corroding. These changes may be immediate, but more often they’re gradual, so measuring and trending resistance changes can be used to predict failure and improve availability. Read the article for other examples of how wired or wireless acoustic sensors can be used to monitor pressure relief valve (PRV) and rupture disc pressure relief events and leaks. He also describes how to monitor online and continuously for corrosion and erosion problems in pipelines and vessels. Finally, he shares how these diagnostics from HART smart instrumentation can be used to augment the traditional 4-20mA analog signal used in safety instrumented systems to provide diagnostic health information about the sensors. You can connect and interact with other functional safety and temperature measurement experts in the Safety Instrumented Systems and Temperature groups in the Emerson Exchange 365 community. Related Posts Extending Measurement Device Stability to 15 Years Temperature Measurement Advanced Diagnostics Redundancy and Diagnostics in Safety Instrumented System Sensors Energy Management with Additional Wireless Measurements Avoiding Flameout and Shutdown in Burner Management Applications When the Heat is on, Control with Wireless The post Instrumentation Diagnostics and Safe, Reliable Operations appeared first on the Emerson Process Experts blog.
↧
Forum Post: Syncade MES
I'd want to consider using video in Syncade. Is anyone currently doing this? How is this handled in DCA? What are the video requirements / limitations?
↧
↧
Blog Post: Fixes for Deadly Deadband
The post, Fixes for Deadly Deadband , first appeared on ControlGlobal.com's Control Talk blog. While there are some cases where deadband is helpful, in most applications the effect is extremely detrimental and confusing. Deadband can arise from any sources either intentionally or inadvertently. Deadband creates deadtime and for certain conditions excessive and persistent oscillations. The increase in loop deadtime is the deadband divided by the rate of change of controller output. The increase in deadtime can increase the peak error and integrated error from a load disturbance. If there are two or more integrators in the system due to integral action in the valve positioner, variable speed drive, controller(s), or process, a limit cycle will develop. The biggest and most troublesome source of deadband is backlash from an on-off or isolation valve (tight shutoff valve) posing as a throttling valve. The positioner seeing feedback from the actuator shaft of such rotary valves often does not realizer the internal closure member (e.g. ball or disk) is not responding due to backlash from the connections between the shaft, stem and ball or disk or the shaft windup from seal friction. The positioner diagnostics say everything is fine even meeting the requirements set by the ISA-75.25.01 Standard for Measuring Valve Response. Creative story telling develops to explain the oscillations in the process. An on-off or isolation valve offers a great advantage when used in series with a throttle valve. Besides achieving tight shutoff, the placement of a quickly stroked completely open or closed on-off or isolation valve close-coupled to the connection into the process eliminates the deadtime and any unbalance between ratioed flows during the start and stop of reactant and reagents enabling more precise composition and pH control. The throttle valve is located at a position that is more accessible for better maintenance and with some straight runs upstream and downstream. The throttle valve straight run requirements are rather minimal but can give a more consistent flow relationship between valve position and flow. For the throttle valve, the best solution is to get rid of the excessive deadband. Given that you are literally and figuratively, stuck with deadband principally when the source is a big valve, an increase in the PID gain will reduce the peak and integrated absolute error (IAE) by increasing the rate of change of the PID output and thus decreasing the additional deadtime from deadband. If there is a limit cycle, increasing the PID gain reduces the amplitude and period of the limit cycle, decreasing the persistent IAE and increasing the ability of downstream volumes to filter out the oscillations. Open loop step tests don’t reveal the additional deadtime but show a decrease in process gain upon a reversal of direction of step change. A filter time can be judiciously added that is less than 20% of the total loop deadtime seen in the test to prevent changes in the PID output from noise exceeding the deadband of the valve. For more on the effects of backlash see the May 2016 Control article “ How to specify control valves that don’t compromise control ” and the recording of the YouTube recording to be posted in June on the “ ISA Mentor Program Webinar Playlist ” of my ISA Mentor WebEx “ ISA-Mentor-Program-WebEx-Best-Control-Valve-Rev0.pdf ”. The article white paper and presentation also shows that an increase in PID gain eliminates an oscillation from poor positioner sensitivity by making changes in the valve signal larger than sensitivity limit. A simple algorithm can be configured to increase the change in PID output by an amount slightly less than the deadband when the output changes direction and the change is greater than the noise band seen in the PID output. The kick of the output upon a change in direction eliminates the deadtime and lost motion from backlash. The practical issue is the deadband may vary with valve position, time, operating conditions, and positioner tuning. These algorithms are often used for Model Predictive Control besides PID control. A lead-lag on the valve signal can reduce the effect of deadband, resolution and positioner sensitivity but the valve movement can quickly become erratic for a lead much larger than the lag time and noise. Often deadband is a parameter in a Variable Speed Drive (VSD) setup to reduce changes in speed from noise. Often deadband is set too large because of a lack of understanding of the detrimental effect. The deadband should be just slightly larger than ½ the noise band seen in the VSD setpoint. Dynamic simulation with a backlash-stiction block and a PID with external reset feedback can show this and much more. The virtual plant is my lab to rapidly explore, discover, prototype and test solutions. I recently went to a Grateful Dead tribute band concert. The “dead heads” were grateful the music of the band was not dead. Keep your control system alive by not succumbing to the deadly deadband.
↧
Blog Post: 산업용 사물인터넷 3단계로 이해하기– 2부
산업용 사물인터넷 3단계로 이해하기– 2부 Bruce Hawkins, Emerson Scott Bruni, independent reliability consultant + 산업용 사물인터넷 3단계로 이해하기 - 1부 보기 2단계: 각 자산의 가치창출(혹은 미창출) 방식을 이해하라플랜트와 공장의 디지털 혁명은 많은 장점이 있습니다. 대부분은 가용성과 신뢰성 측면에 존재합니다. 센싱의 차이를 극복하고 디지털 혁명을 뒷받침하려면 장비의 가용성과 신뢰성에 대해 잘 알아야 합니다. 자산이 고장 나는 방식과 그 이유를 알고 기업 가치 창출에 무엇이 필요한지 알아야 합니다. 오퍼레이션의 가치를 측정하거나 정의하는 일은 생각보다 쉽지 않지만 자산이 현금 흐름(비용과 매출)에 미.......
↧
Forum Post: DELTAV EXPLORER
Respected sir, i am using DeltaV 8.3 version , DCS system working normally . but when i try to open the DELTAV EXPLORER pop up open the Alarm show Connected with the data base server but failed to open a database connection ,please read specific message below and take appropriate action Reason Failed to open the database please check the event log on the Pro+for Details For more information ,click on the detail button even i checked the User name and password is same and correct please help to diagnose the problem khalid javed 00923008339859
↧
Forum Post: RE: Phase Logic Failure message
Could someone help me here ?
↧
↧
Forum Post: RE: Phase Logic Failure message
I'm asking around to see if there's someone that can help shed more light on this. Hopefully I can find someone to respond in the next 24-48 hours.
↧
Forum Post: RE: Phase Logic Failure message
Try Bruce Greenwald or one of the batch engineers.
↧
Forum Post: Bluetooth Temperature measurements interface to AMS 2140
If your AMS 2140 is under Guardian Support, it entitles you to the latest firmware for the AMS 2140 which adds Bluetooth support for temperature readings using the 377BT Bluetooth Temperature Gun from TPI. This handheld device enables fast, accurate temperature measurements across a wide temperature range with the results automatically stored in your AMS 2140 - in either Route or Analyze! This custom interface will allow you to benefit from the following features: Non-contact measurement with laser sight Spot ratio better than 10:1 Measurement range from -18 to 1000⁰C (-58 to 1,832⁰F) Accurate readings ( + 2⁰C or + 2%) Adjustable emissivity
↧
Forum Post: RE: Phase Logic Failure message
Is this the only "Phase Logic Failure: " message you see or you are only questioning what 0 means? This particular case of 0 is more than likely the time the "Clear Failures" was done.
↧
↧
Forum Post: RE: Phase Logic Failure message
Just an end-user here, so this may or may not help... I found that I'd inherited some phases in my facility that were never fully vetted from a messaging stand-point (meaning that there were failures that could occur, but the message describing what the failure was wasn't ever populated). Here is what I had to do to troubleshoot (and again, this may not match your facility's logic). Open your phase in control studio: In DeltaV Explorer, locate the "Unit Module" that contains the phase OR Library --> Advanced definitions --> Phase Classes... "right click" on the phase and select "Open with Control Studio" Expand the phase, and locate the "FAIL_MONITOR" block. This is where the logic resides for all logic failures. In my particular phases (not sure if the is a DeltaV standard, or specific to our logic), we have a FAIL_INDEX with text associated with that. You need to find out whether the individual text is being populated properly. One easy way to do this is to find a phase message that is working in your history, and map back to that to ascertain how the text message is populated. I hope that helps (and is intuitive enough).
↧
Forum Post: RE: Phase Logic Failure message
Matt, I am questioning only about the number. Because I am also able to see 50, 52 out there in Batch History. What does that number indicates?
↧
Blog Post: Enabling Right-the-First-Time Manufacturing
Quality and compliance are indispensable in pharmaceutical and biopharmaceutical manufacturing processes. In a Pharmaceutical Manufacturing magazine article, Crazy About Quality and Compliance? , Emerson’s Michalle Adkins shares how organizational engagement, technologies and work practices must come together for safe, efficient and profitable manufacturing. Michalle opens sharing her experiences in pharmaceutical production management and the difficulties in avoiding problems: …during the planning, manufacturing, testing, reviewing, releasing and storage of a batch… It starts with a clear vision of right-the-first-time manufacturing and understanding the critical attributes. Delivering high-quality products happens: …by putting compliance-ready processes in place from research through commercial manufacturing, within the supply chain process, as well as on the shop floor and in the labs. Many technologies can help play a role as compliance enablers, such as: …data integrity, data analytics, continued process verification, PAT, electronic batch records, electronic log books and predictive analytics… We’ve discussed many of these enabling technologies in earlier Life Sciences-related posts here on the blog. By viewing the manufacturing process from research & development all the way up through commercial-scale manufacturing, some of the compliance enablers include: …build process understanding, design capable processes, and deliver appropriate controls. Design of experiments and PAT are also important pieces of this process. Tools for process control, data collection and recipe management are honed and transferred through the lifecycle. Michalle highlights other dimensions in building quality and compliance into the manufacturing process. These include fault detection and predictive diagnostics, manufacturing business processes, and accurate & reliable measurements & on-line analysis. Read the article for more on these tools and the role of organizational culture, as well as the importance of sharing these tools & processes with other suppliers across the supply chain. You can also connect and interact with other pharmaceutical and biotech industry experts in the Life Sciences group in the Emerson Exchange 365 community. Related Posts Improving Technology Transfer by Earlier Adoption of Standards and Software Platforms Automation Project Justification when not Running at Capacity Accurate and Repeatable Measurements in Pharmaceutical and Biotech Manufacturing Planning Process for Life Science Optimization Projects You Already Asked Me That! Integrating Single Use Equipment More Easily with Control and Manufacturing Execution Systems The post Enabling Right-the-First-Time Manufacturing appeared first on the Emerson Process Experts blog.
↧
Forum Post: RE: FHX to XML converter
I know this is a bit of an old thread, but just wanted to post to say I recently downloaded this tool, so the links still work, and its a great tool...so thank you very much for providing it. Also, if Jack is still monitoring this thread, I did have a bit of a technical question on how he developed the tool that maybe he could answer, just for my own curiosity's sake...and that is how did he handle the ', ", special characters in his tool? I tried using the Emerson supplied converter tool, which I know from reading other posts is not officially supported for doing non Recipe conversions...and the output from that tool has the ', > etc. escaped characters in the XML, which given DeltaV syntax, makes the output pretty unusable if you have anything with expressions in it. But Jack's tool's output has all those special characters in there (except for the & itself, which still shows up escaped). So I was curious how he managed that.
↧
↧
Forum Post: RE: Phase Logic Failure message
The values for this link to the named set "phase_failures" which by default is OK for the value 0. You can look at this named set to see what 50, 52, etc are in your system. You are seeing this is because it is logging the change of state of the FAIL_INDEX of the phase and this is where the "Clear Failures" was given to reset the failure back to OK to be able to restart.
↧
Blog Post: Flowserve PMV D3 Rev 2 DeltaV and AMS Interoperability Test
In Emerson’s continuing commitment to open and interoperable standards, the Flowserve PMV D3 Rev 2 has passed the rigorous and comprehensive testing of the DeltaV and AMS Stress Test labs. Using the Device Installation Kits for Emerson Products website at http://www2.emersonprocess.com/en-US/documentation/deviceinstallkits/Pages/deviceinstallkitsearch.aspx , these fieldbus device files are now available for use.
↧
Forum Post: RE: FHX to XML converter
Hi gtkrueger First, many thanks for these encouragement. Many people download the tool, but I have no feedback related to the use they make of it or any difficulties encountered. It is a pleasure to see that it is useful and appreciated. Personally, I have never successly run the Emerson tool which only completes its task once out of ten. It stall as soon as the FHX is too heavy and no detail about error. My tool may work on a PP or a station. So I took great care not to overload the memory used to store the strings analyzed. The most important problem was the management of quotation marks, " The program reads a portion of the text from the FHX and recognize the keywords and associated data. Some of these data are framed by " in the FHX syntax, and some " can also appear inside data itself. So I count the " occurrence and try to parse de data after check that the string contain an even count of ". The current version 1.1 of the program does not have an optimal management of this search for "and sometimes the search for a complete data area requires a large number of bytes in memory. Some expressions (especially towards the end of the FHX) are very long to analyze (for the FHX of an entire database). I do not have time to fine-tune this part. The second important point is that the program should work without bringing any other file than the executable. Therefore, it was necessary to only use the APIs of the version 2 of the framework Microsoft (framework brought by the installation of DeltaV). See you!
↧